Qaybaha Alaabta

Wire Mesh Pulling Grips

Sharaxaad Gaaban:

Lift sling rigging company produce Pulling Grips,Wire Pulling Grips,Wire Mesh Pulling Grips,cable socks,pulling socks,sock joint,sharabaadada jiidaya fiilada,cable slipper socks,cable knit stockings.

Wire mesh pulling grips for cable, pipe and duct from 9 mm ku 160 mm. Galvanised, 304/316 stainless or aramid mesh, hal il ama laba indhood, 750-8,000 kg capacity at a 5:1 arrin badbaado.

Faahfaahinta Alaabta

Lift sling rigging company produce Pulling Grips,Wire Pulling Grips,Wire Mesh Pulling Grips,cable socks,pulling socks,sock joint,sharabaadada jiidaya fiilada,cable slipper socks,cable knit stockings.

 

 

Pulling Grips

Pulling grips are flexible steel wire mesh sleeves that hold a cable, xadhig, pipe or duct so it can be pulled, lowered or tensioned. Slide the mesh over the end, isha ku adkee, and the weave closes radially on the jacket: the grip tightens as the pull load rises, so nothing has to be clamped or bolted to the cable. We braid them in our own workshop in galvanised steel or AISI 304 / 316 silig aan lahayn, for cable from 9 mm ku 160 mm, with single, labanlaaban, dabacsanaan, wareegta ama indho-daridda.

This page covers the range as a whole: how the mesh holds, which of the five constructions suits the pull you are doing, how to size a grip from the cable diameter and the expected line pull, and what the capacity on the label actually means. Each construction has its own page, linked from the table below.

Pulling grips - wire mesh cable grip with single eye and swaged ferrules
A single-eye wire mesh pulling grip: double-layer cross weave, braided eye, swaged ferrules.

How Wire Mesh Pulling Grips Hold a Cable

There is no mechanism inside a pulling grip. The grip is the weave, and it works in three stages:

  1. dul saar. Balaadhi mesh-ka oo ku riix cidhifka fiilada ilaa uu xadhiggu ka gaadho isha. The mesh has to sit on the full gripping length, not just on the cable tip.
  2. Tension. Load on the eye lengthens the tube slightly and contracts it radially. Every wire in the weave closes on the jacket at once, so the pulling force becomes a uniform clamping force along the whole mesh.
  3. Siideynta. Jiiji xariiqda oo hore u riix shabagga; the weave opens and the grip slides off. No tools, calaamad la'aan, no cut jacket.

Because the load is carried by friction spread over the mesh length, capacity comes from engagement length and the number of mesh layers, not from wire gauge alone. A 3.0 mm wire in a 300 mm mesh holds less than a 2.0 mm wire in a 1200 mesh mm. That is also why a pulling grip can drag a lead-sheathed or thin-wall cable that a clamp would crush, and why the same grip releases without leaving a mark.

Wire mesh pulling grip closed on a cable under tension
The weave closes as tension rises – the grip is the mesh, and it tightens with the load.

Five Constructions, One Principle

Every type below uses the same wire mesh principle. What changes is the head, the way the grip closes, and the material – and those three things decide which pull it suits.

Dhismaha How it closes Isticmaal marka Bogga
Cable pulling sock – madaxa xiran, il keliya Braided closed head, eye at the head Straight pulls into a clean duct or conduit, cable end free Cable pulling socks
Double eye pulling grip Braided closed head with two eyes Two lines, lashing, or a pull that has to be turned in line Double eye grips
Offset eye pulling grip Eye set off the mesh axis Tight manholes and wall entries where the line must clear the duct wall Offset eye grips
Qabashada xadhig-korka Split mesh laced around the cable A cable already installed, or a grip that cannot slide over a free end Lace-up grips
Non-metallic pulling grip Aramid or polyester mesh, bir la'aan Live circuits, fragile insulation, work where steel near conductors is not allowed Non-metallic grips

Material is a separate choice: the closed-head range is available in galvanised steel, AISI 304 ama 316 aan lahayn.

Sizing a Pulling Grip: Three Numbers

Three measurements decide the model, and getting them wrong is the usual reason a grip slips on the first pull.

  • The true outside diameter where the mesh will sit. Measure over the jacket, over any tape or bedding, and over the whole bundle if you are pulling more than one cable. Nominal size is not the gripping size.
  • The mesh length you can engage. A grip needs at least four to five times the cable diameter in mesh contact. Less than that and the load concentrates at the head.
  • The expected line pull at the worst point of the run – start of pull, through bends, up a slope. The published capacity is a working load; keep the pull below it and add margin on a wet, greasy or polished jacket.
Cable outside diameter Minimum mesh engagement (4-5 x OD) Standard mesh length Qaabka
9-16 mm 40-80 mm 300 mm CPS-16
16-25 mm 64-125 mm 450 mm CPS-25
25-38 mm 100-190 mm 600 mm CPS-38
38-50 mm 150-250 mm 700 mm CPS-50
50-75 mm 200-375 mm 900 mm CPS-75
75-100 mm 300-500 mm 1200 mm CPS-100
130-160 mm 520-800 mm 1500 mm CPS-160

Standard range shown. Mesh up to 3000 mm and diameters outside this table are made to order.

Standard Range and Pulling Capacity

The chart below is the standard galvanised range. Capacity is quoted as a working load with a 5:1 safety factor on the breaking strength, measured with the mesh fully engaged on a clean, dry cable.

Qaabka Cable OD (mm) Dhererka mesh (mm) Mesh wire (mm) Awood jiidid (kg)
CPS-16 9-16 300 1.5 750
CPS-25 16-25 450 2.0 1,300
CPS-38 25-38 600 2.0 1,800
CPS-50 38-50 700 2.5 2,500
CPS-75 50-75 900 2.5 3,500
CPS-100 75-100 1200 3.0 5,000
CPS-160 130-160 1500 3.0 8,000

A wet, oily or highly polished jacket reduces friction and therefore capacity – confirm the rating for those conditions before the first pull.

Pulling Grips – Tilmaamid

Halbeegga Tilmaamid
Magaca alaabta Pulling grips / xajin silig / sharabaad jiid jiid / cable stocking
Dhismaha Double-layer cross-woven tubular wire mesh; closed braided head, or split mesh laced closed
Qalabka mesh Galvanised steel wire as standard; AISI 304 ama 316 aan lahayn; aramid or polyester for the non-metallic version
Dhexroorka siliga mesh 1.5 / 2.0 / 2.5 / 3.0 mm, selected by cable diameter and pull load
Dhexroorka fiilada 9-160 mm ee moodooyinka caadiga ah; larger made to order
Dhererka mesh 300 / 450 / 600 / 700 / 900 / 1200 / 1500 mm; caado ilaa 3000 mm
Awood jiidid 750-8,000 kg working load across the standard range
Qodobka badbaadada 5:1 xoogga jabinta lagu qiimeeyay
Isha / nooca madaxa Keli, labanlaaban, dabacsanaan, rotating, offset or thimble eye; braided eye or swaged ferrule
Dahaarka Plain; PVC or rubber coated; colour coating for size coding
Heerkulka shaqada -40 C ilaa +120 C; coated versions to about +70 C
Calaamadayn Qaabka, cable range and capacity on the label or the ferrule tag
Habaynta Mesh length and diameter, wire gauge, nooca isha, calaamadaynta astaanta, private-label packing
Asal ahaan Hal qayb oo ka mid ah Lift Sling Rigging Co., Ltd., Ltd – Taizhou, Jiangsu, Shiinaha

Eye and Head Options

The head decides how the pulling line meets the grip, and it is the part that has to pass a duct mouth, a sheave or a manhole cover.

  • Single braided eye – hal loop, for a straight pull in a clean duct.
  • Laba indhood – two loops for lashing, or for two lines pulled in line.
  • Isha dabacsan – a swaged ferrule eye that articulates, so the grip stays aligned through bends.
  • Isha wareegaysa – lets the cable spin out its own lay on long runs without twisting the mesh.
  • Isha kabaxsan – keeps the line clear of the duct wall where headroom is tight.
  • Thimble eye – a hard wear surface inside the eye where it rubs a hook, shackle or winch line.
Pulling grip with thimble eye and braided mesh body
Thimble eye on a mesh body – the wear surface takes the rub so the eye does not.
Swaged ferrule head on a wire mesh pulling grip
A swaged ferrule head: low build-up, so the grip passes duct entries and sheaves.

Galvanised, Stainless or Non-Metallic

Material is decided by the environment the grip works in, not by the pull load.

Qalabka mesh Deegaanka What it buys you
Galvanised steel wire General site, dhuunta, trench, indoor plant Lowest cost per grip; the zinc layer wears at duct mouths and sheaves over repeated pulls
AISI 304 aan lahayn Wet tunnels, wash-down areas, general outdoor No coating to wear off, no rust staining on white duct or painted pipe
AISI 316 aan lahayn Xeebta, xeebta, chemical and desalination plant Molybdenum for chlorides; the version that survives salt and de-icing spray
PVC ama caag dahaarka leh rinji, polished or stainless pipe Prevents marking; working temperature to about +70 C
Aramid or polyester mesh Live circuits, fragile insulation, fiber No metal anywhere near the conductor

What the Capacity on the Label Means

Every grip is rated at a 5:1 arrin badbaado on its breaking strength, so a CPS-50 with a 2,500 kg capacity has been built to hold about 12,500 kg before it fails. The 2,500 kg figure is the working load: it is what you are permitted to pull, not what the grip can survive.

Two practical consequences. Marka hore, do not use the breaking strength as a target – a grip taken to its break has already damaged the cable and the mesh. Labaad, a pulling grip is a pulling and holding tool, not a lifting sling: unless the model is rated and marked for lifting, keep it on the horizontal pull, the duct and the cable drum.

Fitting and the First Pull

  1. Eeg shabkada, eye and ferrule before every use – fiilooyinka jaban, a deformed eye or a slipped ferrule retire the grip.
  2. Expand the mesh fully and slide it on until the cable end reaches the eye. Half-engagement is the most common cause of a pull that lets go.
  3. Ka dhig jiidashada mid la siman dhidibka mesh; side loading concentrates the grip on one edge of the weave.
  4. Take up the slack slowly and watch the mesh close. If it slips at low load, the grip is too large for the diameter or the jacket is too smooth – stop and re-size rather than pulling harder.
  5. Waligaa ha dhaafin awooda la qiimeeyay, and never stand in line with a loaded pull line.
Worker carrying a wire mesh pulling grip fitted over a cable
A mesh pulling grip carried on the cable – it goes on by hand and comes off the same way.

Kormeerka iyo Hawlgabka

  • Broken or lifted wires anywhere in the weave – the grip has lost section and capacity.
  • A deformed, stretched or opened eye, or a ferrule that has slipped on the rope.
  • Corrosion pitting on galvanised mesh, or a coating worn through to bare wire.
  • Mesh that no longer closes on the cable, or that has been pulled out of shape.
  • Any grip involved in a slip or an overload: retire it, do not re-use it on a lighter job.

Record the pulls and the damage. A grip is cheap next to the cable it is pulling, and a mesh that has been dragged through a rough duct mouth is not the same grip it was on the first pull.

Where Pulling Grips Are Used

  • Soo jiidashada LV, MV iyo fiilada korontada HV, Xakamaynta fiilooyinka iyo fiilada fiber optic-ga iyada oo loo marayo marinnada, dhufaannada iyo kor u kaca
  • Soo jiidashada xidhmooyinka fiilooyinka, xadhig silig ah iyo ulo leh winches, capstans iyo fiilooyinka jiidaya
  • Xakamaynta dhuumaha birta, PVC and PE pipe, mareen, hose and ducting
  • Supporting or lowering smooth cylindrical loads where a clamp would crush or mark the surface
  • Telecom, utility, tunnel, substation, offshore and marine installation work
Wire mesh pulling grip fitted on a plastic pipe for a duct pull
The same grip on PE pipe – mesh grips round sections as readily as it grips cable.

Braiding, Imtixaanka iyo Dukumentiyada

Hal qayb oo ka mid ah Lift Sling Rigging Co., Ltd., Ltd waxa ay ku leedahay Taizhou xadhig tidcan iyo mesh tog, Jiangsu for close to thirty years. Every grip is braided from wire we select, isha waa la tidcaa ama loo rogaa ilaa dherer la xakameeyey, shaybaaradana waa la cadeeyey inta aan la dirin. Warbixinnada hubinta ka hor raridda iyo imtixaanka qolo saddexaad ayaa la diyaarin karaa haddii la codsado; annaga bogga caddaynta wuxuu taxayaa nidaamyada maamulka ee ka dambeeya habka.

OEM is routine: dhererka mesh, mesh diameter, wire gauge, nooca isha, coated colour for size coding, logo marking and private-label packing. Send the cable diameter and the pull load and we will quote the model rather than a range.

Su'aalaha Inta Badan La Isweydiiyo

What are pulling grips used for?

Holding a cable, xadhig, pipe or duct so it can be pulled, lowered or tensioned. The mesh closes on the jacket as the pull load rises, which spreads the gripping force along the cable instead of clamping it at one point.

Is a pulling grip the same as a cable sock?

Haa. Pulling grip, cable sock, cable stocking, mesh grip and pulling stocking all describe the same article: a braided wire mesh tube with an eye at the head. The names come from different trades – cable jointers say sock, riggers say grip.

How do I choose the size?

Measure the true outside diameter where the mesh will sit, then check that the model’s range covers it and that you have at least four to five times the diameter in mesh engagement. A grip that is too large slips; one that is too small will not slide on.

How much can a pulling grip hold?

The standard range runs from 750 kg on the CPS-16 to 8,000 kg on the CPS-160, quoted as working loads at a 5:1 arrin badbaado. Awooddu waxay ku xiran tahay dusha fiilada, mesh length and the number of mesh layers, so confirm the figure for your cable before the first pull.

Will a wire mesh grip damage the cable jacket?

Not in normal use. The load is distributed over the mesh length rather than concentrated, which is why grips are used on lead sheath, thin-wall insulation and fibre. Waayo, rinji, polished or stainless pipe, specify a PVC or rubber coated mesh to avoid surface marking.

Can I fit one to a cable that is already installed?

Haa – use a lace-up or split mesh grip, which is wrapped around the cable and laced closed instead of being slid over a free end. Eeg lace-up hoisting grips bogga.

Can a pulling grip be used for lifting?

Only if the model is rated and marked for lifting. A standard pulling grip is a pulling and holding tool; using an unrated grip as a lifting sling puts a factor of five between the load and a failure that no one has calculated.

Can you make a custom length, eye or branded grip?

Haa. Mesh length from 300 mm ku 3000 mm, cable diameters outside the standard range, kali ah, labanlaaban, dabacsanaan, rotating, offset or thimble eyes, coated colours for size coding, logo marking and private-label packing.

Request a Pulling Grip Quotation

Send the cable or pipe diameter, the mesh length you can engage, the eye type and the expected line pull – plus the environment, if it is wet, salty or likely to mark the surface. We will come back with the model, the capacity and a factory-direct price.

Send your pulling grip specification

Alaabooyinka La Xiriira

 

Fariintaada ka tag

U dhaadhac Top